CILU SUM 150W LED Solar Street Light,12000LM 6500K Solar Powered Pole Light, IP65 Waterproof Security Area Night Lighting for Street Gutter Patio Garden Path,Basketball Court,barn. 5.0 out of 5 stars 2. Get it as soon as Wed, Apr 21. FREE Shipping by Amazon. Scientific Calculator. Web2.0calc.com online calculator provides basic and advanced mathematical functions useful for school or college. You can operate the calculator directly from your keyboard, as well as using the buttons with your mouse. Jignesh Parmar has completed M.Tech (Power System Control), B.E(Electrical). He is FIE,MIE and CEng from Institution of Engineers,India. Membership No:F-1264873,M-1473586.He has more than 19 years experience in Transmission -Distribution-Electrical Energy theft detection-Electrical Maintenance-Electrical Projects (Planning-Designing-Technical Review-coordination -Execution). Pole Height is 13 Meter: On an undivided street, generally Meter, 2.5 Meter or 4 Meter arms are used. Pole Height is 13 Meter: divided Street, typically have a 8 Meter wide center median to divide opposing lanes of traffic. On streets where the light poles are installed in a raised median, two 4 Meter arms oriented 180° apart are used.
- Street Lighting Calc 2000
- Street Lighting Calc 2019
- Street Lighting Calc 2019
- Street Lighting Calc 2017
- Street Lighting Calc 2 Series
Section 6: Spacing of Light Poles
Anchor: #i1004657Standard Spacing for Freeways and Complete Interchange Lighting
For freeway lighting, TxDOT has standard spacings for conventional light poles to provide the minimum AASHTO-recommended illuminance levels. If higher light levels are needed, the spacing should be calculated with lighting design software.
50 ft. poles with 400W EQ LED luminaires may be spaced 270 ft. apart to provide the minimum recommended freeway illuminance levels. This will extend up to 60 ft. across the roadway from the luminaire. If wider roadways need to be lit, the spacing should be calculated with lighting design software.
40 ft. poles with 250W EQ LED luminaires may be spaced 220 ft. apart to provide the minimum recommended freeway illuminance levels. This will extend up to 50 ft. across the roadway from the luminaire. If wider roadways need to be lit, the spacing should be calculated with lighting design software.
Anchor: #i1004680Standard Spacing for Roadways Other than Freeways
To determine the required illumination levels for roadways other than freeways, use the tables in Section 2 of this chapter, the AASHTO Roadway Lighting Design Guide, or ANSI/IES RP-8-14, Roadway Lighting. An illumination program capable of calculating luminance or illuminance levels is required to determine if adequate illumination levels have been achieved. White keyboard for mac.
Anchor: #i1004695Street Lighting Calc 2000
Merge and Diverge Lanes
For partial interchange lighting, the first light pole for merge and diverge lanes should begin at the end of the weave area and continue to within 50 feet of the painted gore, as shown in Figure 6-2.
Figure 6-2. Typical placement for partial interchange lighting, 40 foot luminaire poles at merge and diverge lanes.
Anchor: #i1004717Lighting Near Overpasses
Poles supporting lighting for roadways beneath overpasses should be placed at least 20 feet from the overpass to reduce glare on the overpass.
Street Lighting Calc 2019
Anchor: #i1004727Determining Mounting Height
Mounting height depends on the number of lanes to be lighted. The designer must use the mounting height that allows for adequate illumination levels. If proper lighting cannot be achieved with one pole, the designer should consider using additional poles to provide proper coverage.
Description
Electric street lighting has been standardized since very recently (the 1987 NFC 17-200 French standard). “Quality” and sustainability safeguards for construction are regulated. All people involved operating on a street lighting installation – installers, inspection bodies or building owners – must be particularly vigilant about the risk of indirect contact (Electrostatic). Besides standard compliance, the customer requires a cost-controlled installation. Therefore it is imperative to avoid cable and protection oversizing. To meet efficiently these requirements through a successfully completed working method, companies are now integrating normative and powerful software for designing secure facilities.
Trace Software International Solutions
elec calc™ EP is an electrical grid calculation software for outdoor lighting installations in accordance with current standards (French NF C17-200 and UTE C17-205 guide). Redshift for cinema 4d mac.
elec calc™ EP is a complete and easy to use professional tool, which meets the needs of engineering offices, local administrations’ technical departments, local organizations for electrical network supervision and maintenance and installation inspection organizations.
elec calc™ ep is designed for electricians to size their outdoor lighting installations. elec calc™ EP allows the sizing of cables and protections while taking into account the voltage drops and the short-circuit currents according to the distribution of light fixtures. It also provides information on the compliance status through a clear and user-friendly interface.
elec calc™ EP can be used to:
- Design, optimize and control an outdoor lighting installation.
- Size the entire installation network based on electrical constraints:
– Voltage drops,
– Short-circuit currents,
– Distribution of lights,
– Type of light fixtures. - Edit required documents, drawings and calculation notes to ensure the installation validation and compliance.
elec calc™ ep was developed with the technical collaboration of Inéo Réseaux Ouest, a GDF-Suez Group company involved in the development and distribution of electricity.
Benefits
As a new-generation software, elec calc™ ep works in real-time with instant responses.